Marknadens största urval
Snabb leverans

Development of Conductng Polymer Based Nucleic Acid Biosensors

Om Development of Conductng Polymer Based Nucleic Acid Biosensors

Nucleic acid biosensors have been found to have interesting possibilities for applications in various fields including environmental and medical screening. The two types of analysis used for the nucleic acid biosensors are : (a) detection of genotoxicants/ DNA damage (b) detection of DNA hybridization. For the detection of genotoxicants, the double stranded calf thymus DNA has been electrochemically entrapped into conducting polymers like Polypyrrole (PPy) and Polyaniline (PANI) films to detect chlorpyrifos and malathion. Compared to DNA-PPy, DNA-PANI electrodes have better detection limit for chlorpyrifos and malathion (0.5 ppb and 0.01 ppm, respectively) within 30s, and are stable for about 6 months. The PNA and DNA probes specific to M. tuberculosis have been immobilized onto the PPy and PANI films prepared onto ITO glass for detection of complementary target. The obtained detection limit is about 0.1attomole within 30s and electrodes could detect the genomic DNA of M. tuberculosis in serum samples up to 2.5 pg/¿l within about 60s at 300 C and can be used 8¿9 times.

Visa mer
  • Språk:
  • Engelska
  • ISBN:
  • 9783838380513
  • Format:
  • Häftad
  • Sidor:
  • 196
  • Utgiven:
  • 8. juli 2010
  • Mått:
  • 152x229x11 mm.
  • Vikt:
  • 295 g.
  Fri leverans
Leveranstid: 2-4 veckor
Förväntad leverans: 17. december 2024

Beskrivning av Development of Conductng Polymer Based Nucleic Acid Biosensors

Nucleic acid biosensors have been found to have interesting possibilities for applications in various fields including environmental and medical screening. The two types of analysis used for the nucleic acid biosensors are : (a) detection of genotoxicants/ DNA damage (b) detection of DNA hybridization. For the detection of genotoxicants, the double stranded calf thymus DNA has been electrochemically entrapped into conducting polymers like Polypyrrole (PPy) and Polyaniline (PANI) films to detect chlorpyrifos and malathion. Compared to DNA-PPy, DNA-PANI electrodes have better detection limit for chlorpyrifos and malathion (0.5 ppb and 0.01 ppm, respectively) within 30s, and are stable for about 6 months. The PNA and DNA probes specific to M. tuberculosis have been immobilized onto the PPy and PANI films prepared onto ITO glass for detection of complementary target. The obtained detection limit is about 0.1attomole within 30s and electrodes could detect the genomic DNA of M. tuberculosis in serum samples up to 2.5 pg/¿l within about 60s at 300 C and can be used 8¿9 times.

Användarnas betyg av Development of Conductng Polymer Based Nucleic Acid Biosensors



Hitta liknande böcker
Boken Development of Conductng Polymer Based Nucleic Acid Biosensors finns i följande kategorier:

Gör som tusentals andra bokälskare

Prenumerera på vårt nyhetsbrev för att få fantastiska erbjudanden och inspiration för din nästa läsning.